Methane

(CH4)

Smart Sensor SA1-CH4

Model SA1 smart sensor modules are designed to detect and monitor various gases in ambient air. The modules consist of a target specific gas detection sensor and a microprocessor-based signal conditioning circuit. Both are housed in a metallic enclosure fitted with gold plated connecting pins. The “Smart Sensor Module” is factory programmed for a specific gas and range of sensitivity. On power up the gas type, measurement range and previous zero and span calibration data points are read by the transmitter facilitating a fully automated startup. The modules can be used with any of Safeguard Analytics gas detection transmitters.

Catalytic Bead

Detector Type:  Catalytic Bead
Detection Method: Diffusion
Range of Sensitivity: 0-100 % LEL
Response Time: T50 10s; T90 ≤ 30s
Accuracy:   ± 5 % of Reading
Zero Drift: < 2% per month
Span Drift: < 2% per month
Temperature Range: -40°C to +70°C; -40°F to 158°F
Humidity Range: 15% to 95% RH non-condensing
Pressure Range: 1 Atm ± .1
Input Power:  ~ 3.5 to 5 VDC
Power Consumption: 2.64 milliwatts
Detector Life Expectancy:  >2 Years
Detector Warranty:  1 Year


ItemDescription
SA1-CPS-100Combustible Gas Detector, 0-100% LEL (Catalytic Pellistor) SmartSensor Module
SA1-CH4v-LELMethane Gas Detector, 0-100% by Volume (NDIR) Smart Sensor Module
SA1-CH4-LELMethane Gas Detector, 0-100% LEL (NDIR) Smart Sensor Module

Non-Dispersed Infrared

Detector Type:  Non-Dispersed Infrared (NDIR)
Detection Method: Diffusion
Range of Sensitivity: 0-100% LEL
Response Time: T90 ≤ 30s
Accuracy: ± 2% of FS
Zero Drift: < 2% per month (In clean air)
Span Drift: < 2% per month (In clean air)
Temperature Range: -30°C to +60°C; -22°F to 140°F
Humidity Range: 0% to 95% RH non-condensing
Pressure Range: 1 Atm ± .1
Input Power:  ~ 3.5 to 5 VDC
Power Consumption: <280 milliwatts
Detector Life Expectancy:  >5 Years
Detector Warranty:  5 Years

 


Coming Soon


 


ItemDescription
SA1-C2H4-LELEthylene Infrared Detector, 0-100% LEL (NDIR) Smart Sensor Modules